logo
Found 90 products for "

rigid endoscope repair

"
Kwaliteit Certificering voor de reparatie van medische apparatuur Fabriek

Certificering voor de reparatie van medische apparatuur

The courses we organize and their contents are as follows. COURSE: Rigid scope Repair Training Course Brands: KARL STORZ,Olympus,Stryker,Richard Wolf,Smith & Nephew,Aesculap,Conmed Duration: 5 Days / 4 hours per day (20 hours total) Course Schedule: Courses run on demand. We open the course when you ...

Kwaliteit Olympus A70940A Autoclaveerbare Arthroscoop voor reparatie Fabriek

Olympus A70940A Autoclaveerbare Arthroscoop voor reparatie

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

Kwaliteit Olympus A4674A Autoclaveerbare Hysteroscoop voor reparatie Fabriek

Olympus A4674A Autoclaveerbare Hysteroscoop voor reparatie

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the ...

Kwaliteit Karl Storz 27005BA Cystoscope for repair Fabriek

Karl Storz 27005BA Cystoscope for repair

Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...

Kwaliteit Reparatie van medische hulpmiddelen Olympus CF-H190L Colonoscoop voor reparatie Fabriek

Reparatie van medische hulpmiddelen Olympus CF-H190L Colonoscoop voor reparatie

Olympus CF-H190L Colonoscope for repair,SN:261****. Fault:Light bundle broken,biopsy tube worn,water air tube leakage,bending section deformation,wire helix tube worn. Solution:Replace the bending section,wire,helix tube,air tube and rubber.PS:Warranty for replace parts only. Repair time:7 working ...

Kwaliteit Reparatie van medische hulpmiddelen Fabriek

Reparatie van medische hulpmiddelen

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in ...

Kwaliteit GE 4D3C-L 4D Convex Transducer voor reparatie Fabriek

GE 4D3C-L 4D Convex Transducer voor reparatie

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome ...

Kwaliteit GE 4C-RS abdominale probe voor reparatie Fabriek

GE 4C-RS abdominale probe voor reparatie

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS ...

Kwaliteit S5-2 Hartsonde voor reparatie Fabriek

S5-2 Hartsonde voor reparatie

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain ...